Hg | Mercury
Analysis
0.00 µg/l
Setpoint
0 µg/l
Choose your Habitat here
Choose your Problem here
Unwanted heavy metals | Analysis | Setpoint | ||
---|---|---|---|---|
Hg Mercury | Mercury | 0.00 µg/l | 0 µg/l | |
Se Selenium | Selenium | 0.00 µg/l | 0 µg/l | |
Cd Cadmium | Cadmium | 0.00 µg/l | 0 µg/l | |
Sn Tin | Tin | 2.77 µg/l | 0 µg/l | |
Sb Antimony | Antimony | 0.00 µg/l | 0 µg/l | |
As Arsenic | Arsenic | 0.00 µg/l | 0 µg/l | |
Al Aluminium | Aluminium | 17.82 µg/l | 0 - 60 µg/l | |
Pb Lead | Lead | 0.00 µg/l | 0 µg/l | |
Ti Titanium | Titanium | 0.00 µg/l | 0 µg/l | |
Cu Copper | Copper | 0.00 µg/l | 0 µg/l |
0.00 µg/l
0 µg/l
0.00 µg/l
0 µg/l
0.00 µg/l
0 µg/l
2.77 µg/l
0 µg/l
0.00 µg/l
0 µg/l
0.00 µg/l
0 µg/l
17.82 µg/l
0 - 60 µg/l
0.00 µg/l
0 µg/l
0.00 µg/l
0 µg/l
0.00 µg/l
0 µg/l
Macro-Elements | Analysis | Setpoint | ||
---|---|---|---|---|
Na Sodium | Sodium | 10819.00 mg/l | 10000 - 11300 mg/l | |
Ca Calcium | Calcium | 477.70 mg/l | 415 - 520 mg/l | |
Mg Magnesium | Magnesium | 1383.00 mg/l | 1320 - 1500 mg/l | |
K Potassium | Potassium | 433.80 mg/l | 380 - 480 mg/l | |
Br Bromide | Bromide | 45.04 mg/l | 64 mg/l | |
B Boron | Boron | 4.43 mg/l | 4.5 mg/l | |
Sr Strontium | Strontium | 11.50 mg/l | 8 - 12 mg/l | |
S Sulphur | Sulphur | 600.50 mg/l | 900 mg/l |
10819.00 mg/l
10000 - 11300 mg/l
477.70 mg/l
415 - 520 mg/l
1383.00 mg/l
1320 - 1500 mg/l
433.80 mg/l
380 - 480 mg/l
45.04 mg/l
64 mg/l
4.43 mg/l
4.5 mg/l
11.50 mg/l
8 - 12 mg/l
600.50 mg/l
900 mg/l
Li-Group | Analysis | Setpoint | ||
---|---|---|---|---|
Li Lithium | Lithium | 203.40 µg/l | 200 µg/l | |
Ni Nickel | Nickel | 1.23 µg/l | 5 µg/l | |
Mo Molybdenum | Molybdenum | 10.18 µg/l | 12 µg/l |
203.40 µg/l
200 µg/l
1.23 µg/l
5 µg/l
10.18 µg/l
12 µg/l
I-Group | Analysis | Setpoint | ||
---|---|---|---|---|
V Vanadium | Vanadium | 3.62 µg/l | 0 - 3 µg/l | |
Zn Zinc | Zinc | 1.36 µg/l | 0 - 5 µg/l | |
Mn Manganese | Manganese | 0.00 µg/l | 0 - 3 µg/l | |
I Iodine | Iodine | 8.80 µg/l | 30 - 90 µg/l |
3.62 µg/l
0 - 3 µg/l
1.36 µg/l
0 - 5 µg/l
0.00 µg/l
0 - 3 µg/l
8.80 µg/l
30 - 90 µg/l
Fe-Group | Analysis | Setpoint | ||
---|---|---|---|---|
Cr Chromium | Chromium | 0.00 µg/l | 0 µg/l | |
Co Cobalt | Cobalt | 0.00 µg/l | 0 µg/l | |
Fe Iron | Iron | 0.00 µg/l | 0 µg/l |
0.00 µg/l
0 µg/l
0.00 µg/l
0 µg/l
0.00 µg/l
0 µg/l
Ba-Group | Analysis | Setpoint | ||
---|---|---|---|---|
Ba Barium | Barium | 285.90 µg/l | 0 - 10 µg/l | |
Be Beryllium | Beryllium | 0.00 µg/l | 0 µg/l |
285.90 µg/l
0 - 10 µg/l
0.00 µg/l
0 µg/l
Si-Group | Analysis | Setpoint | ||
---|---|---|---|---|
Si Silicon | Silicon | 804.40 µg/l | 0 - 200 µg/l |
804.40 µg/l
0 - 200 µg/l
Nutrient-Group | Analysis | Setpoint | ||
---|---|---|---|---|
P Phosphorus | Phosphorus | 0.00 µg/l | 6 - 23 µg/l | |
PO4 Phosphate | Phosphate | 0.000 mg/l | 0.018 - 0.07 mg/l |
0.00 µg/l
6 - 23 µg/l
0.000 mg/l
0.018 - 0.07 mg/l
We have detected low levels of P/PO4 along with high levels of Silicon.
Check for possible contamination source. To help you in finding the source of error, we have listed the most frequent sources of contamination for silicon (sorted in descending order of frequency):
1. RO/DI Supply
2. Iron based phosphate remover (not RowaPhos or PhosBan)
3. SIPORAX Type media
4. Activated Carbon
5. Ceramics
Check the possible sources of error and try to avoid them.
The usage of PO4 reducing media can cause problems as your PO4 is already low.
In case of problems we recommend to remove/reduce the phosphate absorber from the system and to increase feeding.
For problems with Cyanobacteria, the product that best suits your system is:
TRITON Organic Supplements P Beta
For a fish tank without algae/Cyanobacteria problems the product that is best suited is:
TRITON Organic Supplements P Alpha
Please contact us for further support on hello@triton.de
We detected elements in your water that can be harmful for your tank.
More information about each element is listed below.
To remedy this we recommend carrying out 6 x 15% water changes with Tropic Marin Pro salt or Red Sea Salt (blue bucket), spread over 6 weeks
We have detected low levels of P/PO4 along with high levels of Barium.
Check for possible contamination source. To help you in your search for the source of error, we have listed the most common sources of Barium (sorted in descending order of frequency):
1. Phosphate iron-based (except ROWAphos or PhosBan)
2. Contaminated salts
3. Contaminated trace elements, in particular strontium
4. Dried fishfood
To remedy this we recommend carrying out 6 x 15% water changes with Tropic Marin Pro salt or Red Sea Salt (blue bucket), spread over 6 weeks
Your Vanadium levels are too high.
Check for possible contamination source. To assist you in finding the source of error, we have listed the most common sources of vanadium (sorted in descending order of frequency):
1. Trace element overdose
2. Reef ceramics
3. Contaminated salts
Your Sulphur levels are slightly low.
Monitor with future ICP-OES tests.
Your Bromine levels are slightly low.
WARNING! Dosage only to be carried out by advanced reef keepers.
Due to the possible hazardous nature of dosing Bromine the dosage amounts include a safety factor to ensure that the risk of overdose is reduced. This may result in further dosing being required with subsequent ICP testing.
Please follow the directions on the Dose tab.
High levels of Tin have been found in your system.
As Tin can be very dangerous to you aquarium you should first try to find the contamination source. To help you in finding the source of error, we have listed the most common sources of tin (sorted in descending order of frequency):
1. Contaminated trace elements
2. Metals near or in the aquarium (as rusty clamps or screws)
3. Contaminated salts
We have detected a lack of iodine.
A Iodine dose can have the following benefits for your aquarium:
- Improves overall health of SPS corals and macroalgae
- Promotes metabolic processes in the reef aquarium
- Can be helpful against parasites and inhibit their reproduction
To restore the natural value, please refer to our recommended dosage.
We recommend the corrective dosage be carried out over 2 days. For the first day the dosage should be 10ml. On the last day please use 0.24ml.
We recommend a daily maintenance dose of 1.02ml. If this dose is very low, then this can be alternatively be dosed weekly (daily dose x7).
The analysis has found a low phosphorus / phosphate level in the aquarium.
In case of problems we recommend to remove/reduce the phosphate absorber from the system and to increase feeding.
For problems with Cyanobacteria, the product that best suits your system is:
TRITON Organic Supplements P Beta
For a fish tank without algae/Cyanobacteria problems the product that is best suited is:
TRITON Organic Supplements P Alpha
Please contact us for further support on hello@triton.de
We recommend the corrective dosage be carried out over 4 days. For the first 3 days the daily dosage should be 1ml. On the last day please use 0.80ml.
We have detected a lack of boron.
A boron dosage can have the following benefits for your aquarium:
- Stabilization of the pH value in the aquarium
- Can promote the colour and health of SPS and LPS
To restore the natural value, please refer to our recommended dosage.
We recommend the corrective dosage of 17.50ml for 1 day.
We have detected a lack of molybdenum.
A molybdenum dose may have the following advantages for your aquarium:
- Can promote enzymatic processes in the reef aquarium
- Can promote the color of SPS and LPS
- Too high a dosage of molybdenum can be detrimental to the aquarium, please dose carefully.
To restore the natural value, please refer to our recommended dosage.
We recommend the corrective dosage of 18.20ml for 1 day.
We have detected a lack of manganese.
A Manganese dose may have the following advantages for your aquarium:
- Can be useful for keeping LPS corals, for example, Goniopora respond very positively to Manganese dosage
- Can promote better polyp extension
To restore the natural value, please refer to our recommended dosage.
To keep this value, refer to our maintenance dose. For calculating the maintenance dose proceed as follows:
1 Test: dose maintenance dose xml
2 Test: old maintenance dosing xml (from the 1st test) + new maintenance dose (from the 2nd test) xml dosing.
3 Test:: old maintenance dosing xml (from the 1st test) + old maintenance dosing xml (from the 2nd test) + new maintenance dose xml meter (from the 3rd Test). Thereafter, the dosage should not be increased, even though the analysis indicates a value of 0.
We recommend the corrective dosage be carried out over 2 days. For the first 2 days the daily dosage should be 10ml.
We recommend a daily maintenance dose of 1.67ml. If this dose is very low, then this can be alternatively be dosed weekly (daily dose x7).
Warning, dangerous element for the aquarium. Dosage for professional, experienced aquarists only!
A nickel dose may have the following advantages for your aquarium:
- Can improve the color image of coral
- Can improve the overall health of LPS and SPS corals
Attention, the concentration of nickel in natural seawater is so low that it can not be detected. If a dose is desired, begin with the recommended dosage listed below and test the value regularly in our laboratory. If nickel are detected, they have overdosed and should adjust the dose immediately. You can increase the dosage of nickel slowly until they see a positive effect.
We recommend the corrective dosage be carried out over 2 days. For the first day the dosage should be 20ml. On the last day please use 17.70ml.
We have detected a lack of zinc.
A zinc dosage may have the following advantages for your aquarium:
- Can promote enzymatic processes in reef aquariums
- Can promote color and health of LPS and SPS corals
To restore the natural value, please refer to our recommended dosage.
To keep this value, please refer to our maintenance dose. For calculating the maintenance dose proceed as follows:
1st Test: dose maintenance dose xml
2nd Test: old maintenance dosing xml (from the 1st test) + new maintenance dose (from the 2nd test) XML.
3. Test:: old maintenance dosing xml (from the 1st test) + old maintenance dosing xml (from the 2nd test) + new maintenance dose xml meter (from the 3rd Test). Thereafter, the dosage should not be increased, even though the analysis indicates a value of 0
We recommend the corrective dosage of 2.64ml for 1 day.
We recommend a daily maintenance dose of 0.26ml. If this dose is very low, then this can be alternatively be dosed weekly (daily dose x7).